Microbial contamination of interior elevator buttons in a university
-
摘要:
目的 调查某高校公用电梯内部按钮表面的微生物污染情况,为电梯消毒卫生管理提供数据参考。 方法 连续4个季度对某高校公用电梯内部按钮进行采样(共计140台次电梯),参照《公用场所卫生检验第4部分:公共用品用具微生物》(GB/T 18204.4—2013)检测按钮表面的细菌总数、大肠菌群及金黄色葡萄球菌,参照《公共场所卫生指标及限值要求》(GB 37488—2019)中公共用品用具的卫生要求进行评价。 结果 某高校公用电梯内部按钮的携菌率高达98.57%,19.29%的按钮携菌量超过公共用品用具规定限值(300 CFU/25 cm2);细菌总数、大肠菌群、金黄色葡萄球菌总合格率分别为80.71%,99.29%,95.71%;不同季节金黄色葡萄球菌的合格率差异有统计学意义(χ2=12.11,P < 0.01),夏季金黄色葡萄球菌合格率最低(82.86%);行政楼、教学楼和综合楼电梯内部按钮的细菌总数、大肠菌群、金黄色葡萄球菌指标合格率差异均无统计学意义(χ2值分别为3.53,2.37,2.08,P值均>0.05)。 结论 某高校公用电梯内部按钮存在细菌污染,携菌率高、携菌量大且有致病菌的存在。相关部门需加强学校公用电梯内部按钮的消毒频率和效果监测,师生使用电梯后需增强手卫生意识。 Abstract:Objective To investigate the microbial contamination on the interior elevator buttons in a university, and to provide data reference for elevator disinfection and sanitation management. Methods The interior elevator buttons in a university were sampled for 4 consecutive quarters (140 elevators in total). The total number of bacteria, coliform bacteria and Staphylococcus aureus on the surface of elevator buttons are tested by referring to "Sanitary Inspection Methodsfor Public Places-Part IV: Microorganisms for Public Utensils" (GB/T 18204.4-2013). The results were evaluated with reference to the hygienic requirements for public utensils and utensils in "Sanitation Indicators and Limit Requirements for Public Places"(GB 37488-2019). Results The bacteria contamination rate of the interior buttons of public elevators in the university was 98.57%, and 19.29% of which exceeded the maximum level for public appliances (300 CFU/25 cm2). The total qualified rate of total bacteria, coliform bacteria and Staphylococcus aureus were 80.71%, 99.29% and 95.71% respectively. The qualified rate of Staphylococcus aureus varied by season(χ2=12.11, P < 0.01), and the qualified rate of Staphylococcus aureus was the lowest in summer(82.86%). The pass rates of the three elevator sanitation indicators in the administrative building, teaching building and comprehensive building did not vary by different building functions (total number of bacteria: χ2=3.53, coliform: χ2=2.37, Staphylococcus aureus: χ2=2.08, P>0.05). Conclusions Bacterial contamination was found in most of the interior buttons of public elevators in university, with vast number of bacteria and pathogenic bacteria. Relevant departments need to strengthen the disinfection frequency and effect monitoring of the interior buttons of public elevators in schools. All the staffs and students in the university need to increase their awareness of hand hygiene after using the elevator. -
Key words:
- Elevators and escalators /
- Bacteria /
- Environmental pollution /
- Public health
1) 利益冲突声明 所有作者声明无利益冲突。 -
表 1 某高校不同季节公用电梯内部按钮微生物合格率比较
Table 1. Comparison of qualified rates of microorganisms in internal buttons of public elevators in different seasons in a university
检测时间 采样量/台次 细菌总数 大肠菌群 金黄色葡萄球菌 夏 35 26(74.29) 35(100.00) 29(82.86) 秋 35 28(80.00) 34(97.14) 35(100.00) 冬 35 28(80.00) 35(100.00) 35(100.00) 春 35 31(88.57) 35(100.00) 35(100.00) χ2值 2.34 2.83* 12.11* P值 0.56 1.00 < 0.01 注:()内数字为合格率/%;*为Fisher确切概率法。 表 2 不同功能性建筑电梯内部按钮微生物合格率比较
Table 2. Comparison of microbial qualification rates of internal buttons in elevators of different functional buildings
功能性建筑 采样量/台次 细菌总数 大肠菌群 金黄色葡萄球菌 行政楼 20 19(95.00) 20(100.00) 18(90.00) 教学楼 44 36(81.82) 43(97.73) 43(97.73) 综合楼 76 58(76.32) 76(100.00) 73(96.05) χ2值 3.53 2.37 2.08 P值 0.16 0.46 0.34 注:()内数字为合格率/%。 -
[1] KANDEL C E, SIMOR A E, REDELMEIER D A. Elevator buttons as unrecognized sources of bacterial colonization in hospitals[J]. Open Med, 2014, 8(3): 81-86. [2] 李勤, 欧剑鸣, 宋铁, 等. 电梯工在一次SARS疫情爆发中的传播作用[J]. 中华流行病学杂志, 2003, 24(12): 43. https://www.cnki.com.cn/Article/CJFDTOTAL-ZHLX200312017.htmLI Q, OU J M, SONG T, et al. The spreading role of elevator workers in a SARS outbreak[J]. Chin J Epidemiol, 2003, 24(12): 43. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-ZHLX200312017.htm [3] XIE C J, ZHAO H J, LI K B, et al. The evidence of indirect transmission of SARS-CoV-2 reported in Guangzhou, China[J]. BMC Public Health, 2020, 20(1): 1202. doi: 10.1186/s12889-020-09296-y [4] 黄亮宇, 钟雪珊, 赖志胜, 等. 新型冠状病毒肺炎感染者环境污染特征分析[J]. 中国公共卫生, 2021, 37(4): 664-667. https://www.cnki.com.cn/Article/CJFDTOTAL-ZGGW202104020.htmHUANG L Y, ZHONG X S, LAI Z S, et al. Characteristics of SARS-CoV-2 contamination on inanimate surfaces in environment surrounding COVID-19 cases and asymptomatic infected individuals[J]. Chin J Public Health, 2021, 37(4): 664-667. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-ZGGW202104020.htm [5] 钟健, 祝梅芳, 黄辉萍, 等. 门诊电梯按钮面板污染现状及清洁消毒效果分析[J]. 中国卫生标准管理, 2018, 9(22): 127-129. https://www.cnki.com.cn/Article/CJFDTOTAL-WSBZ201822057.htmZHONG J, ZHU M F, HUANG H P, et al. Effect evaluation of surface disinfection towel on elevator button panel of outpatient and bacteria contamination of touch surface[J]. Chin Health Stand Manag, 2018, 9(22): 127-129. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-WSBZ201822057.htm [6] 吴柳, 杨竹兰, 罗娟, 等. 某医院电梯按钮微生物污染调查[J]. 中国消毒学杂志, 2018, 35(1): 32-34. https://www.cnki.com.cn/Article/CJFDTOTAL-ZGXD201801011.htmWU L, YANG Z L, LUO J, et al. Investigation on microbial contamination of elevator button in some hospital[J]. Chin J Disinfect, 2018, 35(1): 32-34. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-ZGXD201801011.htm [7] 陈怡丽, 黄楚梅, 骆恒芳, 等. 医院电梯按钮的细菌污染调查[J]. 中国卫生检验杂志, 2015, 25(20): 3563-3564, 3567. https://www.cnki.com.cn/Article/CJFDTOTAL-ZWJZ201520056.htmCHEN Y L, HUANG C M, LUO H F, et al. Research on bacterial contamination of hospital elevator button[J]. Chin J Health Lab Tech, 2015, 25(20): 3563-3564, 3567. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-ZWJZ201520056.htm [8] 郭景玉, 董磊, 何柳, 等. 部队医院电梯按钮细菌污染情况调查及部分污染细菌耐药分析[J]. 空军医学杂志, 2019, 35(6): 519-520, 543. https://www.cnki.com.cn/Article/CJFDTOTAL-ZJZY201906018.htmGUO J Y, DONG L, HE L, et al. Investigation on bacterial contamination of elevator buttons and analysis of drug resistance of some contaminated bacteria in military hospital[J]. Med J Air Forc, 2019, 35(6): 519-520, 543. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-ZJZY201906018.htm [9] 国家质量监督检验检疫总局, 中国国家标准化管理委员会. 公共场所卫生检验方法第4部分: 公共用品用具微生物: GB/T 18204.4—2013[S]. 北京: 中国标准出版社, 2013.General Administration of Quality Supervision, Inspection and Quarantine of the PRC, Standardization Administration of the PRC. Examination methods for public places-Part 4: microorganism on a surface of public articles: GB/T 18204.4-2013[S]. Beijing: Standards Press of China, 2013. (in Chinese) [10] 国家市场监督管理总局, 中国国家标准化管理委员会. 公共场所卫生指标及限值要求: GB 37488—2019[S]. 北京: 中国标准出版社, 2019.State Administration for Market Regulation, Standardization Administration of the PRC. Hygienic indicators and limits for public places: GB 37488-2019[S]. Beijing: Standards Press of China, 2019. (in Chinese) [11] 于潞, 杨敏, 李默, 等. 金黄色葡萄球菌与大肠埃希菌在不同环境下存活率的比较[J]. 中国病原生物学杂志, 2016, 11(2): 110-115. https://www.cnki.com.cn/Article/CJFDTOTAL-ZISC201602005.htmYU L, YANG M, LI M, et al. Comparison of the survival of Gram-positive bacteria and Gram-negative bacteria in different environments[J]. Chin J Pathogen Biol, 2016, 11(2): 110-115. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-ZISC201602005.htm [12] 李强, 周柯, 孙菲. 军医大学本科生鼻腔定植金黄色葡萄球菌和其他可培养菌群的筛查[J]. 中国感染控制杂志, 2019, 18(10): 930-935. https://www.cnki.com.cn/Article/CJFDTOTAL-GRKZ201910006.htmLI Q, ZHOU K, SUN F. Screening for nasal colonized Sta phylococcus aureus and other cultivable bacteria in students from military medical university[J]. Chin J Infect Control Vol, 2019, 18(10): 930-935. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-GRKZ201910006.htm [13] 石之驎, 彭鑫, 黄敏, 等. 抗击新冠疫情中后勤工作对控制院内感染的作用[J]. 中国研究型医院, 2021, 8(2): 5-9. https://www.cnki.com.cn/Article/CJFDTOTAL-YJXU202102004.htmSHI Z L, PENG X, HUANG M, et al. The role of logistic work in the control of nosocomial infection in the fight against the COVID-19 epidemic[J]. Chin J Res Hospit, 2021, 8(2): 5-9. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-YJXU202102004.htm [14] 吴柳, 杨竹兰, 张波, 等. 安装速干手消剂装置对减少医院电梯按钮污染的效果[J]. 中国感染控制杂志, 2020, 19(10): 909-913. https://www.cnki.com.cn/Article/CJFDTOTAL-GRKZ202010010.htmWU L, YANG Z L, ZHANG B, et al. Effect of installing alcohol-based handrub devices on reducing the contamination of hospital elevator buttons[J]. Chin J Infect Control, 2020, 19(10): 909-913. (in Chinese) https://www.cnki.com.cn/Article/CJFDTOTAL-GRKZ202010010.htm -

计量
- 文章访问数: 717
- HTML全文浏览量: 330
- PDF下载量: 56
- 被引次数: 0